CodeChronicle

OBC 2006 Division B

9.27.4.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 9.27.4. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 9.27.4. — Pro

9.27.4. — Caulking

Content not available for this version.

9.27.4.1. — Required Caulking

(1) Caulking shall be provided where required to prevent the entry of water into the structure.

(2) Caulking shall be provided between masonry, siding or stucco and the adjacent door and window frames or trim, including sills unless such locations are completely protected from the entry of rain.

(3) Caulking shall be provided at vertical joints between different cladding materials unless the joint is suitably lapped or flashed to prevent the entry of rain.

Text · e-Laws consolidated snapshot

9.27.4.2. — Materials

(1) Caulking shall be,

(a) a non-hardening type suitable for exterior use,

(b) selected for its ability to resist the effects of weathering, and

(c) compatible with and adhere to the substrate to which it is applied.

(2) Caulking shall conform to,

(a) CGSB 19-GP-5M, “Sealing Compound, One Component, Acrylic Base, Solvent Curing”,

(b) CAN/CGSB-19.13-M, “Sealing Compound, One Component, Elastomeric, Chemical Curing”,

(c) CGSB 19-GP-14M, “Sealing Compound, One Component, Butyl-Polyisobutylene Polymer Base, Solvent Curing”, or

(d) CAN/CGSB-19.24-M, “Multicomponent, Chemical Curing Sealing Compound”.

Text · e-Laws consolidated snapshot