OBC 2006 › Division B
9.20.8.5.
Version 0 — in force 31 December 2006
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 9.20.8.5.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 9.20.8.5.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
Provenance
OBC 1997 · continues from 9.20.8.5. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
OBC 2012 · continues as 9.20.8.5. — Pro
9.20.8.5. — Distance to Edge of Supporting Members
(1) Masonry veneer of hollow units resting on bearing support shall not project more than,
(a) 30 mm beyond the supporting base where the veneer is not less than 90 mm thick, and
(b) 12 mm beyond the supporting base where the veneer is less than 90 mm thick.
(2) Masonry veneer of solid units resting on bearing support shall not project more than one third of the width of the veneer.
(3) Where the masonry veneer described in Sentence (2) is rough stone masonry,
(a) the projection shall be measured as the average projection of the units, and
(b) the width of the veneer shall be measured as the average width of the veneer.
Text · e-Laws consolidated snapshot
Provenance
OBC 1997 · continues from 9.20.8.5. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
OBC 2012 · continues as 9.20.8.5. — Pro