OBC 2006 › Division B
9.20.5.2.
Version 1 — in force 1 January 2010
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 9.20.5.2.
- Version
- v1
240. (1) Subject to subsections (2), (3), (4), (5), (6) and (7), this Regulation comes into force on the later of January 1, 2010 and the day this Regulation is filed.
Read directly from the regulation's own commencement section.
O. Reg. 503/09 · commencement 240(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 9.20.5.2.
- Version
- v1
240. (1) Subject to subsections (2), (3), (4), (5), (6) and (7), this Regulation comes into force on the later of January 1, 2010 and the day this Regulation is filed.
Read directly from the regulation's own commencement section.
O. Reg. 503/09 · commencement 240(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
Provenance
OBC 1997 · continues from 9.20.5.2. — Pro
Base · O. Reg. 350/06 · ext v0 →
O. Reg. 503/09, cl. 164 · ext ← current
In force 2010-01-01
OBC 2012 · continues as 9.20.5.2. — Pro
9.20.5.2. — Lintels or Arches
(1) Masonry over openings shall be supported by steel, reinforced concrete lintels or masonry arches designed to support the imposed loads.
(2) Except as permitted in Sentences (3) and (6), steel angle lintels supporting masonry above openings shall conform to Table 9.20.5.2.A.
(3) Steel angle lintels supporting masonry veneer above openings shall conform to Table 9.20.5.2.B.
(4) Steel lintels described in Sentences (2) and (3) shall,
(a) have even and level bearing and shall have not less than 150 mm length of bearing at end supports, and
(b) bear on masonry, concrete or steel.
(5) Steel angle lintels supporting masonry shall be primed or painted or otherwise protected from corrosion.
(6) Steel beams supporting masonry veneer and wood stud walls above openings shall conform to Table 9.20.5.2.C.
(7) Steel beams described in Sentence (6) shall be supported at each end by a steel column, and have a minimum 6 mm plate welded to the flange to support the masonry veneer.
Notes toTable 9.20.5.2.C.:
(1)These spans assume that the beam supports the veneer, a wood stud wall and a maximum specified roof live load of 2.3 kN/m.
(2)Where the steel beam carries floor loads or larger roof loads, refer to Article 9.23.4.3.v1
Editor's note
O. Reg. 503/09 amends Table 9.20.5.2.A. effective January 1, 2010 (adding the unit 'mm' to the angle-dimension column headings) but does not change the notes to Table 9.20.5.2.c., so the e-Laws consolidation differences in those notes described for the prior version carry forward to this version.
Text · e-Laws consolidated snapshot
Column 1 | Column 2 | Column 3 | Column 4 | Col. 5 | Col. 6 | Col. 7 | Col. 8 | Col. 9 | Col. 10 | Col. 11 | |||
Clear Span(1)(3) | Exterior Angles, mm | Wall Thickness,mm | Interior Angles, mm | ||||||||||
for Brick | for Stone | Maximum Floor Loads per Metre of Span in Newtons(2)(4)(5) | |||||||||||
100 mm | 100 mm + 50 mm stone facing | ||||||||||||
None | 3 650 | 7 300 | 10 950 | 14 600 | 18 250 | 21 900 | |||||||
No Floor Load | |||||||||||||
1 200 mm or less | L-90 × 90 × 6 | L-125 × 90 × 8 | 203 | L-90 | L-90 | L-90 | L-100 | L-125 | L-125 | L-125 | |||
× 90 | × 90 | × 90 | × 90 | × 90 | × 90 | × 90 | |||||||
× 6 | × 6 | × 8 | × 8 | × 8 | × 10 | × 13 | |||||||
305 | 2Ls-90 | 2Ls-90 | 2Ls-90 | 2Ls-90 | 2Ls-90 | 2Ls-100 | 2Ls-100 | ||||||
× 90 | × 90 | × 90 | × 90 | × 90 | × 90 | × 90 | |||||||
× 8 | × 8 | × 8 | × 8 | × 8 | × 8 | × 8 | |||||||
1 500 mm | L-90 × 90 × 8 | L-125 × 90 × 8 | 203 | L-90 | L-90 | L-125 | L-125 | L-125 | L-150 | — | |||
× 90 | × 90 | × 90 | × 90 | × 90 | × 90 | — | |||||||
× 8 | × 8 | × 8 | × 10 | × 13 | × 10 | — | |||||||
305 | 2Ls-90 | 2Ls-90 | 2Ls-90 | 2Ls-125 | 2Ls-125 | 2Ls-125 | 2Ls-125 | ||||||
× 90 | × 90 | × 90 | × 90 | × 90 | × 90 | × 90 | |||||||
× 8 | × 8 | × 8 | × 8 | × 8 | × 8 | × 10 | |||||||
1 800 mm | L-100 × 90 × 8 | L-125 × 125 × 8 | 203 | L-100 | L-125 | L-125 | L-150 | ||||||
× 90 | × 90 | × 90 | × 100 | ||||||||||
× 8 | × 8 | × 8 | × 10 | ||||||||||
305 | 2Ls-100 | 2Ls-100 | 2Ls-125 | 2Ls-125 | 2Ls-125 | 2Ls-150 | 2Ls-150 | ||||||
× 90 | × 90 | × 90 | × 90 | × 90 | × 100 | × 100 | |||||||
× 8 | × 8 | × 8 | × 8 | × 10 | × 10 | × 10 | |||||||
2 100 mm | L-100 × 90 × 8 | L-125 × 125 × 8 | 203 | L-100 | L-125 | L-150 | |||||||
× 90 | × 90 | × 100 | |||||||||||
× 8 | × 10 | × 10 | |||||||||||
305 | 2Ls-100 | 2Ls-125 | 2Ls-125 | 2Ls-150 | 2Ls-150 | ||||||||
× 90 | × 90 | × 90 | × 100 | × 100 | |||||||||
× 8 | × 10 | × 10 | × 10 | × 10 | |||||||||
2 400 mm | L-125 × 90 × 8 | L-125 × 125 × 8 | 203 | L-125 | L-150 | ||||||||
× 90 | × 100 | ||||||||||||
× 8 | × 10 | ||||||||||||
305 | 2Ls-125 | 2Ls-125 | 2Ls-150 | ||||||||||
× 90 | × 90 | × 100 | |||||||||||
× 8 | × 13 | × 10 | |||||||||||
2 700 mm | L-125 × 90 × 10 | L-125 × 125 × 10 | 203 | L-125 | |||||||||
× 90 | |||||||||||||
× 10 | |||||||||||||
305 | 2Ls-125 | 2Ls-150 | |||||||||||
× 150 | × 100 | ||||||||||||
× 10 | × 10 | ||||||||||||
3 000 mm | L-150 × 100 × 10 | L-125 × 125 × 13 | 203 | L-150 | |||||||||
× 100 | |||||||||||||
× 10 | |||||||||||||
305 | 2Ls-150 | ||||||||||||
× 100 | |||||||||||||
× 10 | |||||||||||||
Notes to Table 9.20.5.2.A.:
(1)See Sentence 9.20.5.2.(4).
(2)Omit floor load in lintel when distance to bottom of floor construction is greater than width of opening.
(3)Interior and exterior angles in 200 mm walls and interior angles in 300 mm walls are bolted together when clear span is over 1 800 mm.
(4)When masonry lighter than brick is used over interior angles floor load may be increased by the difference in weight per square metre times the width of the opening. Not generally available.
(5)Interior angles have been designed for floor load plus brick masonry of height equal to width of opening.
(6)fs = 138 Mpa., Deflection maximum = 1/700 span.
(7)The figures in the Table indicating wall thickness and angle cross-section are in mm.
Column 1 | Column 2 | Column 3 | Column 4 | Column 5 | Column 6 |
Minimum Angle Size, mm | 70 mm | 90 mm | 100 mm | ||
Vertical Leg | Horizontal Leg | Thickness | Brick | Brick | Stone |
90 | 75 | 6 | 2.55 | — | — |
90 | 90 | 6 | 2.59 | 2.47 | 2.30 |
100 | 90 | 6 | 2.79 | 2.66 | 2.48 |
125 | 90 | 8 | 3.47 | 3.31 | 3.08 |
125 | 90 | 10 | 3.64 | 3.48 | 3.24 |
125 | 90 | 13 | 3.82 | 3.59 | 3.33 |
150 | 90 | 10 | 4.06 | 3.82 | 3.54 |
150 | 90 | 13 | 4.32 | 4.07 | 3.77 |
150 | 100 | 13 | 4.37 | 4.12 | 3.82 |
180 | 100 | 10 | 4.57 | 4.30 | 3.99 |
180 | 100 | 13 | 4.87 | 4.59 | 4.25 |
Column 1 | Column 2 | Column 3 | Column 4 |
Section | 70 mm Brick | 90 mm Brick | 100 mm Stone |
W 150 × 22 | 4.23 | 4.09 | 3.92 |
W 150 × 30 | 4.68 | 4.52 | 4.32 |
W 200 × 27 | 5.26 | 5.08 | 4.84 |
W 200 × 31 | 5.57 | 5.37 | 5.11 |
W 200 × 36 | 5.70 | 5.49 | 5.23 |
Provenance
OBC 1997 · continues from 9.20.5.2. — Pro
Base · O. Reg. 350/06 · ext v0 → compare
O. Reg. 503/09, cl. 164 · ext ← current
In force 2010-01-01
OBC 2012 · continues as 9.20.5.2. — Pro