OBC 2006 › Division B
9.20.17.6.
Version 1 — in force 2 April 2007
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 9.20.17.6.
- Version
- v1
80. (1) Subject to subsection (2), this Regulation comes into force on the day it is filed.
Read directly from the regulation's own commencement section.
O. Reg. 137/07 · commencement 80(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 9.20.17.6.
- Version
- v1
80. (1) Subject to subsection (2), this Regulation comes into force on the day it is filed.
Read directly from the regulation's own commencement section.
O. Reg. 137/07 · commencement 80(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
Provenance
New in this edition — no OBC 1997 predecessor
Base · O. Reg. 350/06 · ext v0 →
O. Reg. 137/07, cl. 60 · ext ← current
In force 2007-04-02
OBC 2012 · continues as 9.20.17.6. — Pro
9.20.17.6. — Anchoring of Roof Framing to Top of Flat Insulating Concrete Form Walls
(1) Roof framing supported on the top of flat insulating concrete form walls shall be fixed to the top plates, which shall be anchored to the wall with anchor bolts,
(a) not less than 12.7 mm in diameter, and
(b) spaced not more than 1 200 mm o.c.
(2) The anchor bolts described in Sentence (1) shall be placed in the centre of the flat insulating concrete form wall and shall be embedded not less than 100 mm into the concrete.
(3) Attachment of roof framing to wood top plates shall be in accordance with Table 9.23.3.4.
Text · e-Laws consolidated snapshot
Provenance
New in this edition — no OBC 1997 predecessor
Base · O. Reg. 350/06 · ext v0 → compare
O. Reg. 137/07, cl. 60 · ext ← current
In force 2007-04-02
OBC 2012 · continues as 9.20.17.6. — Pro