CodeChronicle

OBC 2006 Division B

9.19.2.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 9.19.2. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 9.19.2. — Pro

9.19.2. — Access

Content not available for this version.

9.19.2.1. — Access

(1) Every attic or roof space shall be provided with an access hatch where the attic or roof space measures not less than,

(a) 10 m² in area,

(b) 1 000 mm in length or width, and

(c) 600 mm in height over at least the area described in Clauses (a) and (b).

(2) The hatch required in Sentence (1) shall be not less than 550 mm by 900 mm except that, where the hatch serves a single dwelling unit, the hatch the hatch may be reduced to 0.32 m2 in area with no dimension less than 545 mm.

(3) Hatchways to attic or roof spaces shall be fitted with doors or covers.

Text · e-Laws consolidated snapshot