9.18.3.1. — Ventilation of Unheated Crawl Spaces

(1) Unheated crawl spaces shall be ventilated by natural or mechanical means.

(2) Where an unheated crawl space is ventilated by natural means, ventilation shall be provided to the outside air by not less than 0.1 m² of unobstructed vent area for every 50 m² of floor area.

(3) Vents shall be,

(a) uniformly distributed on opposite sides of the building, and

(b) designed to prevent the entry of snow, rain and insects.