CodeChronicle

OBC 2006 Division B

9.17.2.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 9.17.2. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 9.17.2. — Pro

9.17.2. — General

Content not available for this version.

9.17.2.1. — Location

(1) Columns shall be centrally located on a footing conforming to Section 9.15.

Text · e-Laws consolidated snapshot

9.17.2.2. — Lateral Support

(1) Columns shall be securely fastened to the supported member to reduce the likelihood of lateral differential movement between the column and the supported member.

(2) Except as permitted by Sentence (3), columns shall be laterally supported,

(a) directly, or

(b) by connection to the supported members.

(3) Columns need not be provided with lateral support as described in Sentence (2) where,

(a) the length of the columns are not more than 600 mm measured from the finished ground to the underside of the supported member, and

(b) the columns support a deck with no superstructure.

Text · e-Laws consolidated snapshot