CodeChronicle

OBC 2006 Division B

9.15.1.1.

Version 1 — in force 2 April 2007

In force · amended
Verified · covered Verified against the 2007-04-02–2007-06-30 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 9.15.1.1. — Pro

Base · O. Reg. 350/06 · ext v0 →

O. Reg. 137/07, cl. 53(2) · ext ← current

In force 2007-04-02

O. Reg. 503/09, cl. 155 · ext v2 →

In force 2010-01-01

Next: O. Reg. 503/09, cl. 155 · ext (not in force until 2010-01-01) v2 →

OBC 2012 · continues as 9.15.1.1. — Pro

9.15.1.1. — General

Comparing versions

Changed text stands out · unchanged is dimmed

v1 O. Reg. 137/07

Earlier · viewing · 2007-04-02

(1) Except as provided in Articles 9.15.1.2. and 9.15.1.3., this Section applies to,

(a) concrete or unit masonry foundation walls and concrete footings not subject to surcharge,

(i) on stable soils with an allowable bearing pressure of 75 kPa or greater, and

(ii) for buildings of wood frame or masonry construction,

(b) wood frame foundation walls and wood or concrete footings not subject to surcharge,

(i) on stable soils with an allowable bearing pressure of 75 kPa or greater, and

(ii) for buildings of wood frame construction, and

(c) flat insulating concrete form foundation walls and concrete footings not subject to surcharge,

(i) on stable soils with an allowable bearing pressure of 100 kPa or greater, and

(ii) for buildings of light frame or flat insulating concrete form construction that are not more than 2 storeys in building height, with a maximum floor to floor height of 3 m, and containing only a single dwelling unit.

(2) Foundations for applications other than as described in Sentence (1) shall be designed in accordance with Section 9.4.

(3) Where a foundation is erected on filled ground, peat or sensitive clay, the footing sizes shall be designed in conformance with Section 4.2.

(4) For the purpose of Sentence (3), sensitive clay means the grain size of the majority of the particles is smaller than 0.002 mm, including leda clay.

v2 O. Reg. 503/09

Later · 2010-01-01

(1) Except as provided in Articles 9.15.1.2. and 9.15.1.3., this Section applies to,

(a) concrete or unit masonry foundation walls and concrete footings not subject to surcharge,

(i) on stable soils with an allowable bearing pressure of 75 kPa or greater, and

(ii) for buildings of wood frame or masonry construction,

(b) wood frame foundation walls and wood or concrete footings not subject to surcharge,

(i) on stable soils with an allowable bearing pressure of 75 kPa or greater, and

(ii) for buildings of wood frame construction, and

(c) flat insulating concrete form foundation walls and concrete footings not subject to surcharge,

(i) on stable soils with an allowable bearing pressure of 75 kPa or greater, and

(ii) for buildings of light frame or flat insulating concrete form construction that are not more than 2 storeys in building height, with a maximum floor to floor height of 3 m, and containing only a single dwelling unit.

(2) Foundations for applications other than as described in Sentence (1) shall be designed in accordance with Section 9.4.

(3) Where a foundation is erected on filled ground, peat or sensitive clay, the footing sizes shall be designed in conformance with Section 4.2.

(4) For the purpose of Sentence (3), sensitive clay means the grain size of the majority of the particles is smaller than 0.002 mm, including leda clay.