8.9.3. — Maintenance

Content not available for this version.

8.9.3.1. — Scope

(1) The requirement of this Subsection are in addition to the requirements of Subsection 8.9.1.

Text · e-Laws consolidated snapshot

8.9.3.2. — General

(1) Every sewage system shall be maintained so that,

(a) the construction of the sewage system remains in accordance with,

(i) the basis on which the construction and use of the sewage system was approved or required under this Act or predecessor legislation, as the case may be, and

(ii) the requirements of the manufacturer of the sewage system, and

(b) all components of the sewage system function in their intended manner.

(2) The land in the vicinity of a sewage system shall be maintained in a condition that will not cause damage to, or impair the functioning of, the sewage system.

Text · e-Laws consolidated snapshot

8.9.3.3. — Interceptors

(1) Every grease interceptor referred to in Article 8.1.3.1.v1 shall be maintained so that the grease retained is below the rated capacity of the interceptor.

Text · e-Laws consolidated snapshot

8.9.3.4. — Class 4 Sewage Systems

(1) Septic tanks and other treatment units shall be cleaned whenever sludge and scum occupy 1/3 of the working capacity of the tank.

Text · e-Laws consolidated snapshot

8.9.3.5. — Shallow Buried Trenches

(1) The pressure head at the furthest point from the pump in all distribution pipes shall be checked for compliance with Article 8.7.6.2. and the design specification at least every 36 months.

O. Reg. 350/06, Division B, Part 8.