CodeChronicle

OBC 2006 Division B

8.7.4.1.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 8.7.4.1. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 8.7.4.1. — Pro

8.7.4.1. — Loading Requirements

(1) The area described in Sentence 8.7.4.2.(1) shall be designed such that the loading rate does not exceed, for soil having a percolation time set out in Column 1 of Table 8.7.4.1.A., the maximum value set out opposite it in Column 2 of Table 8.7.4.1.A.

Text · e-Laws consolidated snapshot

Table 8.7.4.1.A. Loading Rates for Fill Based Absorption Trenches and Filter Beds Forming Part of Sentences 8.7.4.1.(1) and 8.7.5.2.(2)

Column 1

Column 2

Percolation Time (T) of Soil, min/cm

Loading Rates, (L/m2)/day

1 < T ≤ 20

10

20 < T ≤ 35

8

35 < T ≤ 50

6

T > 50

4