CodeChronicle

OBC 2006 Division B

8.4.2.3.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 8.4.2.3. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 8.4.2.3. — Pro

8.4.2.3. — Sizing

(1) A Class 2 sewage system shall be designed and constructed so that the loading rate to the side walls shall be not more than the value calculated using the formula,

where,

LR = loading rate of the sidewalls in litres per day/m2, and

T = percolation time.

Text · e-Laws consolidated snapshot