7.6.3.1. — Design

(1) Except as permitted in Sentences (2) and (3), the size of every pipe in a water distribution system that supplies water to a fixture or device and the flow pressures at the supply openings shall be designed to provide peak demand flow in conformance to Table 7.6.3.1.

(2) A tail piece or connector not more than 750 mm long and not less than ¼ in. inside diameter may be used to supply water to a fixture or device.

(3) A water distribution system that serves not more than a single dwelling unit does not need to conform to Column 3 of Table 7.6.3.1.

(4) No water system between the point of connection with the water service pipe or the water meter and the first branch that supplies a water heater, shall be less than ¾ in. size.

(5) Every pipe that supplies a fixture shall have a capacity that will produce a flow in the fixture that will flush the fixture and keep it in a sanitary condition.

Text · e-Laws consolidated snapshot

Table 7.6.3.1. Pipe Sizing for Water Supply to Fixture/Device Forming Part of Sentences 7.6.3.1.(1) and (3)

Column 1

Column 2

Column 3

Column 4

Column 5

Fixture or Device

Minimum Size of Supply Pipe, in.

Minimum Flow Pressure(1) kPa (gauge)

Hydraulic Load, fixture units

Private Use

Public Use

Bathroom group

    (a) with flush tank

NA

NA

6

-

    (b) with direct flush valve

NA

NA

8

-

Bath tub (with or without shower)

½

50

2

4

Clothes washer

½

100

3

-

Cup Sink

½

50

-

4

Dishwasher, domestic

½

100

3

-

Drinking fountain

3/8

100

-

1

Hose bib or wall hydrant

½

100

(2)

(2)

Laundry tray: 1, 2 or 3 compartments

½

100

2

4

Lavatory

3/8

50

1

2

Shower, single head

½

50

2

4

Sink

    (a) kitchen, domestic

½

50

2

-

    (b) kitchen, commercial

½

50

-

4

    (c) service, slop

½

50

-

3

    (d) service with direct flush valve

¾

100

-

5

Urinal

    (a) with flush tank

½

50

-

3

    (b) with direct flush valve

¾

100

-

5

    (c) with self closing metering valve

½

-

-

-

Water closet

    (a) with flush tank

3/8

50

3

5

    (b) with direct flush valve

1

100

6

10

Notes to Table 7.6.3.1.:

(1)Measured immediately upstream of faucet or supply valve.

(2)A continuous load of 0.38 L/s.