7.5.7.1.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · renumbered from 7.5.6.1. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 7.5.7.1. — Pro

7.5.7.1. — General

(1) The size of every vent pipe shall conform to Table 7.5.7.1.

Text · e-Laws consolidated snapshot

Table 7.5.7.1. Minimum Permitted Size of Vent Pipe Based on Size of Trap Forming Part of Sentence 7.5.7.1.(1)

Column 1

Column 2

Column 3

Size of Trap Served, in.

Minimum Size of Vent Pipe, in.

Maximum Trap Arm, m

1 ¼

1 ¼

1.5

1 ½

1 ¼

1.5

2

1 ½

1.5

3

1 ½

1.8

4

1 ½

3.0

5

2

4.0

6

2