OBC 2006 › Division B
7.5.1.1.
Version 0 — in force 31 December 2006
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 7.5.1.1.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 7.5.1.1.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
Provenance
OBC 1997 · continues from 7.5.1.1. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
OBC 2012 · continues as 7.5.1.1. — Pro
7.5.1.1. — Venting for Traps
(1) Except as provided in Sentences (3) and (4), every trap shall be protected by a vent pipe.
(2) Drainage systems shall be protected by the installation of a system as provided in Subsections 7.5.4. and 7.5.5. by the installation of,
(a) additional circuit vents,
(b) branch vents,
(c) circuit vents,
(d) continuous vents,
(e) dual vents,
(f) fresh air inlets,
(g) headers,
(h) individual vents,
(i) offset relief vents,
(j) relief vents,
(k) stack vents,
(l) vent stacks,
(m) wet vents, or
(n) yoke vents.
(3) A trap that serves a floor drain or hub drain need not be protected by a vent pipe separately where,
(a) the size of the trap is not less than 3 in.,
(b) the length of the fixture drain is not less than 450 mm,
(c) the fall on the fixture drain does not exceed its size, and
(d) the trap is connected to a horizontal drainage pipe that terminates at its upstream end in a 3 in. stack.
(4) A trap need not be protected by a vent pipe,
(a) where it serves,
(i) a subsoil drainage pipe, or
(ii) a storm drainage system, or
(b) where it forms part of an indirect drainage system.
Text · e-Laws consolidated snapshot
Provenance
OBC 1997 · continues from 7.5.1.1. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
OBC 2012 · continues as 7.5.1.1. — Pro