CodeChronicle

OBC 2006 Division B

7.3.4.6.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 7.3.4.6. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 7.3.4.6. — Pro

7.3.4.6. — Support for Underground Horizontal Piping

(1) Except as provided in Sentence (2), nominally horizontal piping that is underground shall be supported on a base that is firm and continuous under the whole of the pipe.

(2) Nominally horizontal piping installed underground that is not supported as described in Sentence (1) may be installed using hangers fixed to a foundation or structural slab provided that the hangers are capable of,

(a) keeping the pipe in alignment, and

(b) supporting the weight,

(i) of the pipe,

(ii) its contents, and

(iii) the fill over the pipe.

Text · e-Laws consolidated snapshot