(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 7.2.6.8.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
Provenance
OBC 1997 · continues from 7.2.6.8. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
OBC 2012 · continues as 7.2.6.8. — Pro
7.2.6.8. — Corrugated Steel Pipe and Couplings
(1) Corrugated steel pipe and couplings shall be certified to CSA G401, “Corrugated Steel Pipe Products”.
(2) Corrugated steel pipe shall only be used underground outside a building in a storm drainage system.
(3) Couplings for corrugated steel pipe shall be constructed so that when installed they shall,
(a) maintain the pipe alignment,
(b) resist the separation of adjoining lengths of pipe,
(c) prevent root penetration, and
(d) prevent the infiltration of surrounding material.
Text · e-Laws consolidated snapshot
Provenance
OBC 1997 · continues from 7.2.6.8. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
OBC 2012 · continues as 7.2.6.8. — Pro