7.2.6.5. — Screwed Cast Iron Water Fittings

Comparing versions

Changed text stands out · unchanged is dimmed

v0 base

Earlier · 2006-12-31

(1) Screwed cast iron water fittings shall conform to ANSI/ASME B16.4, “Gray Iron Threaded Fittings”.

(2) Screwed cast iron water fittings used in a water system shall be cement-mortar lined or galvanized.

(3) Screwed cast iron water fittings shall not be used in a drainage system.

v1 O. Reg. 503/09

Later · viewing · 2010-01-01

(1) Screwed cast iron water fittings shall conform to ANSI/ASME B16.4, “Gray Iron Threaded Fittings, Classes 125 and 250”.

(2) Screwed cast iron water fittings used in a water system shall be cement-mortar lined or galvanized.