CodeChronicle

OBC 2006 Division B

7.2.4.2.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 7.2.4.2. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 7.2.4.2. — Pro

7.2.4.2. — Sanitary T Fittings

(1) A double sanitary T fitting shall not be used to connect the fixture drains of two urinals where no cleanout fitting is provided above the connection. 

(2) No pipe fitting, joint or connection that would tend to intercept solids or reduce the flow through a pipe by more than 10 percent shall be used in a plumbing system.

Editor's note

In Sentence 7.2.4.2.(2), the as-filed O. Reg. 350/06 writes 'percent' (one word); this map reproduces the source as filed. The e-Laws consolidation renders it as 'per cent' (two words), the spelling used elsewhere in the regulation. This spelling difference was not enacted by an amending regulation.