CodeChronicle

OBC 2006 Division B

7.2.10.14.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 7.2.10.14. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 7.2.10.14. — Pro

7.2.10.14. — Vent Pipe Flashing

(1) Flashing fabricated on-site for vent pipes shall be fabricated from,

(a) copper sheet at least 0.33 mm thick,

(b) aluminum sheet at least 0.61 mm thick,

(c) alloyed zinc sheet at least 0.35 mm thick,

(d) lead sheet at least 2.16 mm thick,

(e) galvanized steel sheet at least 0.41 mm thick, or

(f) polychloroprene (neoprene) at least 2.89 mm thick.

(2) Prefabricated flashing for vent pipes shall be certified to CSA B272, “Prefabricated Self-Sealing Vent Flashings”.

Text · e-Laws consolidated snapshot