240. (1) Subject to subsections (2), (3), (4), (5), (6) and (7), this Regulation comes into force on the later of January 1, 2010 and the day this Regulation is filed.
Read directly from the regulation's own commencement section.
O. Reg. 503/09 · commencement 240(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 7.2.10.10.
- Version
- v1
240. (1) Subject to subsections (2), (3), (4), (5), (6) and (7), this Regulation comes into force on the later of January 1, 2010 and the day this Regulation is filed.
Read directly from the regulation's own commencement section.
O. Reg. 503/09 · commencement 240(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
Provenance
OBC 1997 · continues from 7.2.10.10. — Pro
Base · O. Reg. 350/06 · ext v0 →
O. Reg. 503/09, cl. 96 · ext ← current
In force 2010-01-01
OBC 2012 · continues as 7.2.10.10. — Pro
7.2.10.10. — Back-Siphonage Preventers and Backflow Preventers
Comparing versions
Changed text stands out · unchanged is dimmed
v0 base
Earlier · 2006-12-31(1) Except as provided in Sentence (2) back-siphonage preventers and backflow preventers shall be certified to,
(a) CAN/CSA-B64.0, “Definitions, General Requirements and Test Methods for Vacuum Breakers and Backflow Preventers”,
(b) CAN/CSA-B64.1.1, “Vacuum Breakers, Atmospheric Type (AVB)”,
(c) CAN/CSA-B64.1.2, “Vacuum Breakers, Pressure Type (PVB)”,
(d) CAN/CSA-B64.2, “Vacuum Breakers, Hose Connection Type (HCVB)”,
(e) CAN/CSA-B64.2.1, “Vacuum Breakers, Hose Connection Type (HCVB) with Manual Draining Feature,”
(f) CAN/CSA-B64.2.2, “Vacuum Breakers, Hose Connection type (HCVB) with Automatic Draining Feature,”
(g) CAN/CSA-B64.3, “Backflow Preventers, Dual Check Valve with Atmospheric Port Type (DCAP)”,
(h) CAN/CSA-B64.4, “Backflow Preventers, Reduced Pressure Principle Type (RP)”,
(i) CAN/CSA-B64.5, “Backflow Preventers, Double Check Valve Type (DCVA)”,
(j) CAN/CSA-B64.6, “Backflow Preventers, Dual Check Valve Type (DuC)”,
(k) CAN/CSA-B64.7, “Vacuum Breakers, Laboratory Faucet Type (LFVP)”,
(l) CAN/CSA-B64.8, “Backflow Preventers, Dual Check with Intermediate Vent Type (DuCV)”, or
(m) CAN/CSA-B64.10, “Manual for the Selection and Installation of Backflow Prevention Devices”.
(2) Back-siphonage preventers for tank type water closets shall be certified to CAN/CSA-B125, “Plumbing Fittings”.
v1 O. Reg. 503/09
Later · viewing · 2010-01-01(1) Except as provided in Sentence (2) back-siphonage preventers and backflow preventers shall be certified to,
(a) CAN/CSA-B64.0, “Definitions, General Requirements and Test Methods for Vacuum Breakers and Backflow Preventers”,
(b) CAN/CSA-B64.1.1, “Vacuum Breakers, Atmospheric Type (AVB)”,
(c) CAN/CSA-B64.1.2, “Vacuum Breakers, Pressure Type (PVB)”,
(d) CAN/CSA-B64.2, “Vacuum Breakers, Hose Connection Type (HCVB)”,
(e) CAN/CSA-B64.2.1, “Vacuum Breakers, Hose Connection Type (HCVB) with Manual Draining Feature,”
(f) CAN/CSA-B64.2.2, “Vacuum Breakers, Hose Connection type (HCVB) with Automatic Draining Feature,”
(g) CAN/CSA-B64.3, “Backflow Preventers, Dual Check Valve with Atmospheric Port Type (DCAP)”,
(h) CAN/CSA-B64.4, “Backflow Preventers, Reduced Pressure Principle Type (RP)”,
(i) CAN/CSA-B64.5, “Backflow Preventers, Double Check Valve Type (DCVA)”,
(j) CAN/CSA-B64.6, “Backflow Preventers, Dual Check Valve Type (DuC)”,
(k) CAN/CSA-B64.7, “Vacuum Breakers, Laboratory Faucet Type (LFVP)”,
(l) CAN/CSA-B64.8, “Backflow Preventers, Dual Check with Intermediate Vent Type (DuCV)”, or
(m) CAN/CSA-B64.10, “Manual for the Selection and Installation of Backflow Prevention Devices”.
(2) Back-siphonage preventers (anti-siphon fill valves) for tank type water closets shall be certified to CAN/CSA-B125.3, “Plumbing Fittings”.
Provenance
OBC 1997 · continues from 7.2.10.10. — Pro
Base · O. Reg. 350/06 · ext v0 → comparing ×
O. Reg. 503/09, cl. 96 · ext ← current
In force 2010-01-01
OBC 2012 · continues as 7.2.10.10. — Pro