CodeChronicle

OBC 2006 Division B

5.6.1.2.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · split from 5.6.1.2. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

Discontinued — no OBC 2012 successor

5.6.1.2. — Protective Material and Component Properties

(1) Except as provided in Sentence (2), where western cedar shakes or shingles are installed to provide the required protection from precipitation,

(a) shakes shall be not less than No.1 or Handsplit grade, and

(b) shingles shall be not less than No. 2 grade.

(2) Where western cedar shakes or shingles are installed as undercoursing to provide required protection from precipitation on vertical assemblies, they shall be not less than No. 3 grade.

(3) Except as provided in Sentence (4), where eastern white cedar shingles are installed to provide the required protection from precipitation, they shall be not less less than B (clear) grade.

(4) Where eastern white shingles are installed as undercoursing to provide the required protection from precipitation on vertical assemblies, they shall be not less than C grade.

Text · e-Laws consolidated snapshot