CodeChronicle

OBC 2006 Division B

4.1.7.4.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · renumbered from 4.1.8.4. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 4.1.7.4. — Pro

4.1.7.4. — Interior Walls and Partitions

(1) In the design of interior walls and partitions, due consideration shall be given to differences in air pressure on opposite sides of the wall or partition that may result from,

(a) pressure differences between the windward and leeward sides of a building,

(b) stack effects due to a difference in air temperature between the exterior and interior of the building, and

(c) air pressurization by the mechanical services of the building.

Text · e-Laws consolidated snapshot