4.1.5.10. — Concentrated Loads

(1) The specified live load due to possible concentrations of load resulting from the use of an area of floor or roof shall not be less than that listed in Table 4.1.5.10. applied over an area of 750 mm by 750 mm located so as to cause maximum effects, except that for occupancies not listed in Table 4.1.5.10., the concentrations of load shall be determined in accordance with Article 4.1.5.2.

Text · e-Laws consolidated snapshot

Table 4.1.5.10. Specified Concentrated Live Loads on an Area of Floor or Roof Forming Part of Sentence 4.1.5.10.(1)

Column 1

Column 2

Area of Floor or Roof

Minimum Specified Concentrated Load, kN

Roof surfaces

1.3

Floors of classrooms

4.5

Floors of offices, manufacturing buildings, hospital wards and stages

9.0

Floors and areas used by passenger cars

11

Floors and areas used by vehicles not exceeding 3600 kg gross weight

18

Floors and areas used by vehicles exceeding 3600 kg but not exceeding 9000 kg gross weight

36

Floors and areas used by vehicles exceeding 9000 kg gross weight

54

Driveways and sidewalks over areaways and basements

54