OBC 2006 › Division B
3.8.3.4.
Version 0 — in force 31 December 2006
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 3.8.3.4.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next one commenced. What follows is that next version’s commencement — the event that ended this one.
240. (1) Subject to subsections (2), (3), (4), (5), (6) and (7), this Regulation comes into force on the later of January 1, 2010 and the day this Regulation is filed.
Read directly from the regulation's own commencement section.
O. Reg. 503/09 · commencement 240(1)
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 3.8.3.4.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next one commenced. What follows is that next version’s commencement — the event that ended this one.
240. (1) Subject to subsections (2), (3), (4), (5), (6) and (7), this Regulation comes into force on the later of January 1, 2010 and the day this Regulation is filed.
Read directly from the regulation's own commencement section.
O. Reg. 503/09 · commencement 240(1)
Provenance
OBC 1997 · continues from 3.8.3.4. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
O. Reg. 503/09, cl. 53 · ext v1 →
In force 2010-01-01
Next: O. Reg. 503/09, cl. 53 · ext (not in force until 2010-01-01) v1 →
OBC 2012 · continues as 3.8.3.4. — Pro
3.8.3.4. — Ramps
Comparing versions
Changed text stands out · unchanged is dimmed
v0 base
Earlier · viewing · 2006-12-31(1) Ramps located in a barrier-free path of travel shall,
(a) have a minimum width of 900 mm between handrails,
(b) have a maximum gradient of 1 in 12,
(c) have a level area of at least 1 670 mm by 1 670 mm at the top and bottom of a ramp and where a door is located in a ramp, so that the level area extends at least 600 mm beyond the latch side of the door opening, except that where the door opens away from the ramp, the area extending beyond the latch side of the door opening may be reduced to 300 mm,
(d) have a level area at least 1 670 mm long and at least the same width as the ramp,
(i) at intervals of not more than 9 m along its length, and
(ii) where there is an abrupt change in the direction of the ramp,
(e) except as provided in Sentence (2), be equipped with handrails on both sides that shall,
(i) be continuously graspable along their entire length and have circular cross-section with an outside diameter not less than 30 mm and not more than 40 mm, or any non-circular shape with a graspable portion that has a perimeter not less than 100 mm and not more than 155 mm and whose largest cross-sectional dimension is not more than 57 mm,
(ii) be not less than 865 mm and not more than 965 mm high, measured vertically from the surface of the ramp, except that handrails not meeting these requirements are permitted provided they are installed in addition to the required handrail,
(iii) be terminated in a manner that will not obstruct pedestrian travel or create a hazard,
(iv) extend horizontally not less than 300 mm beyond the top and bottom of the ramp,
(v) be provided with a clearance of not less than 40 mm between the handrail and any wall to which it is attached, and
(vi) be designed and constructed such that handrails and their supports will withstand the loading values obtained from the nonconcurrent application of a concentrated load not less than 0.9 kN applied at any point and in any direction for all handrails and a uniform load not less than 0.7 kN/m applied in any direction to the handrail,
(f) except as provided in Sentence (2), have a wall or a guard on both sides and where a guard is provided the guard shall,
(i) be not less than 1 070 mm measured vertically to the top of the guard from the ramp surface, and
(ii) be designed so that no member, attachment or opening located between 140 mm and 900 mm above the ramp surface being protected by the guard will facilitate climbing, and
(g) be provided,
(i) with a curb at least 50 mm high on any side of the ramp where no solid enclosure or solid guard is provided, and
(ii) with railings or other barriers that extend to within 50 mm of the finished ramp surface or have a curb not less than 50 mm high.
(2) Where a ramp serves as an aisleway for fixed seating, the requirements for handrails in Clause (1)(e) need not apply.
(3) Floors or walks in a barrier-free path of travel having a slope steeper than 1 in 20 shall be designed as ramps.
v1 O. Reg. 503/09
Later · 2010-01-01(1) Ramps located in a barrier-free path of travel shall,
(a) have a minimum width of 900 mm between handrails,
(b) have a maximum gradient of 1 in 12,
(c) have a level area of at least 1 670 mm by 1 670 mm at the top and bottom of a ramp and where a door is located in a ramp, so that the level area extends at least 600 mm beyond the latch side of the door opening, except that where the door opens away from the ramp, the area extending beyond the latch side of the door opening may be reduced to 300 mm,
(d) have a level area at least 1 670 mm long and at least the same width as the ramp,
(i) at intervals of not more than 9 m along its length, and
(ii) where there is an abrupt change in the direction of the ramp,
(e) except as provided in Sentence (2), be equipped with handrails on both sides that shall,
(i) be continuously graspable along their entire length and have circular cross-section with an outside diameter not less than 30 mm and not more than 40 mm, or any non-circular shape with a graspable portion that has a perimeter not less than 100 mm and not more than 155 mm and whose largest cross-sectional dimension is not more than 57 mm,
(ii) be not less than 865 mm and not more than 965 mm high, measured vertically from the surface of the ramp, except that handrails not meeting these requirements are permitted provided they are installed in addition to the required handrail,
(iii) be terminated in a manner that will not obstruct pedestrian travel or create a hazard,
(iv) extend horizontally not less than 300 mm beyond the top and bottom of the ramp,
(v) be provided with a clearance of not less than 50 mm between the handrail and any wall to which it is attached, and
(vi) be designed and constructed such that handrails and their supports will withstand the loading values obtained from the nonconcurrent application of a concentrated load not less than 0.9 kN applied at any point and in any direction for all handrails and a uniform load not less than 0.7 kN/m applied in any direction to the handrail,
(f) except as provided in Sentence (2), have a wall or a guard on both sides and where a guard is provided the guard shall,
(i) be not less than 1 070 mm measured vertically to the top of the guard from the ramp surface, and
(ii) be designed so that no member, attachment or opening located between 140 mm and 900 mm above the ramp surface being protected by the guard will facilitate climbing, and
(g) be provided,
(i) with a curb at least 50 mm high on any side of the ramp where no solid enclosure or solid guard is provided, and
(ii) with railings or other barriers that extend to within 50 mm of the finished ramp surface or have a curb not less than 50 mm high.
(2) Where a ramp serves as an aisleway for fixed seating, the requirements for handrails in Clause (1)(e) need not apply.
(3) Floors or walks in a barrier-free path of travel having a slope steeper than 1 in 20 shall be designed as ramps.
Provenance
OBC 1997 · continues from 3.8.3.4. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
O. Reg. 503/09, cl. 53 · ext v1 →
In force 2010-01-01 comparing ×
Next: O. Reg. 503/09, cl. 53 · ext (not in force until 2010-01-01) v1 →
OBC 2012 · continues as 3.8.3.4. — Pro