OBC 2006 › Division B
3.7.4.4.
Version 0 — in force 31 December 2006
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 3.7.4.4.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 3.7.4.4.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
Provenance
OBC 1997 · continues from 3.7.4.4. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
OBC 2012 · continues as 3.7.4.4. — Pro
3.7.4.4. — Plumbing Fixtures for Care or Detention Occupancies
(1) The number of water closets and lavatories required for Group B, Division 1 occupancies shall be determined on the basis of the special needs of these occupancies.
(2) In a Group B, Division 2 or 3 occupancy, washrooms shall be provided so that each washroom,
(a) serves not more than four patients or residents,
(b) is accessible from patients’ or residents’ sleeping rooms,
(c) contains one water closet, and
(d) contains one lavatory.
(3) The number of water closets required for employees in Group B, Division 2 or 3 occupancies shall conform to Table 3.7.4.4.
Text · e-Laws consolidated snapshot
Column 1 | Column 2 |
Number of Persons of Each Sex | Minimum Number of Water Closets for Each Sex |
up to 9 | 1 |
10 to 24 | 2 |
25 to 49 | 3 |
50 to 74 | 4 |
75 to 100 | 5 |
over 100 | 6 plus 1 for each additional increment of 30 persons of each sex in excess of 100 |
Provenance
OBC 1997 · continues from 3.7.4.4. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
OBC 2012 · continues as 3.7.4.4. — Pro