CodeChronicle

OBC 2006 Division B

3.7.4.4.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 3.7.4.4. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 3.7.4.4. — Pro

3.7.4.4. — Plumbing Fixtures for Care or Detention Occupancies

(1) The number of water closets and lavatories required for Group B, Division 1 occupancies shall be determined on the basis of the special needs of these occupancies.

(2) In a Group B, Division 2 or 3 occupancy, washrooms shall be provided so that each washroom,

(a) serves not more than four patients or residents,

(b) is accessible from patients’ or residents’ sleeping rooms,

(c) contains one water closet, and

(d) contains one lavatory.

(3) The number of water closets required for employees in Group B, Division 2 or 3 occupancies shall conform to Table 3.7.4.4.

Text · e-Laws consolidated snapshot

Table 3.7.4.4. Water Closets in Group B, Division 2 or 3 Occupancies Forming Part of Sentence 3.7.4.4.(3)

Column 1

Column 2

Number of Persons of Each Sex

Minimum Number of Water Closets for Each Sex

up to 9

1

10 to 24

2

25 to 49

3

50 to 74

4

75 to 100

5

over 100

6 plus 1 for each additional increment of 30 persons of each sex in excess of 100