OBC 2006 › Division B
3.5.
Version 0 — in force 31 December 2006
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 3.5.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 3.5.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
Provenance
OBC 1997 · continues from 3.5. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
OBC 2012 · continues as 3.5. — Pro
3.5. — Vertical Transportation
Content not available for this version.
3.5.1. — General
Content not available for this version.
3.5.1.1. — Scope
(1) This Section applies to vertical transportation facilities installed in a building, including elevators, escalators and dumbwaiters.
(2) Elevators in a building within the scope of Subsection 3.2.6.v1 shall conform to Articles 3.2.6.8.v1 and 3.2.6.9.v1
Text · e-Laws consolidated snapshot
3.5.2. — Elevator Requirements
Content not available for this version.
3.5.2.1. — Required Elevator
(1) In a Group B, Division 2 or 3 occupancy, if sleeping rooms or patient or resident services are provided on more than one floor level and the floor levels are not connected by ramps conforming to Article 3.8.3.4., such floor levels shall be served by at least one elevator that is large enough to accommodate a stretcher in a horizontal position.
Text · e-Laws consolidated snapshot
3.5.2.2. — Barrier-Free Design
(1) Passenger elevators shall conform to Appendix E of CSA B44, “Safety Code for Elevators”.
Text · e-Laws consolidated snapshot
3.5.3. — Fire Separations
Content not available for this version.
3.5.3.1. — Fire Separations for Elevator Hoistways
(1) Except as permitted by Sentence (2), a vertical service space used as an elevator hoistway shall be separated from all other portions of each adjacent storey by a fire separation having a fire-resistance rating conforming to Table 3.5.3.1. for the fire-resistance rating required by Subsection 3.2.2. for,
(a) the floor assembly above the storey, or
(b) the floor assembly below the storey, if there is no floor assembly above.
(2) Passenger elevators, other than those provided for fire fighters in accordance with Article 3.2.6.9.v1, are permitted to be located within or adjacent to the opening of an interconnected floor space protected in conformance with the requirements of Articles 3.2.8.3. to 3.2.8.11., Sentences 3.2.8.2.(4)v1v2 and (6) without being enclosed in a hoistway separated from the remainder of the interconnected floor space provided the elevator machinery is located in a room separated from the remainder of the building by a fire separation whose fire-resistance rating is not less than that required for hoistways by Sentence (1).
(3) Where the elevator described in Sentence (2) has doors opening into storeys above or below the interconnected floor space it shall be protected by vestibules conforming to the requirements of Sentence 3.2.8.5.(1).
Text · e-Laws consolidated snapshot
Column 1 | Column 2 | Column 3 |
Fire-Resistance Rating of Fire Separation Required for Floor Assembly | Minimum Fire-Resistance Rating of Vertical Service Space for Elevator Hoistway | Minimum Fire-Resistance Rating of Vertical Service Space for Dumbwaiters |
less than 45 min | 45 min | --- |
45 min | 45 min | 45 min |
1 h | 1 h | 45 min |
1.5 h | 1 h | 1 h |
2 h or more | 1.5 h | 1 h |
3.5.3.2. — Vertical Service Spaces for Dumbwaiters
(1) A vertical service space containing a dumbwaiter shall be separated from all other portions of each adjacent storey by a fire separation having a fire-resistance rating conforming to Table 3.5.3.1.v1 for the fire-resistance rating required by Subsection 3.2.2. for,
(a) the floor assembly above the storey, or
(b) the floor assembly below the storey, if there is no floor assembly above.
Text · e-Laws consolidated snapshot
3.5.3.3. — Fire Separations for Elevator Machine Rooms
(1) Except as permitted by Sentence (2), a room containing elevator machinery shall be separated from all other parts of the building by a fire separation having a fire-resistance rating not less than that required for the vertical service space containing the elevator hoistway.
(2) A room containing elevator machinery need not be separated from the elevator hoistway that it serves provided the room and the hoistway are separated from all other parts of the building by a fire separation having a fire-resistance rating not less than that required for the vertical service space containing the elevator hoistway.
Text · e-Laws consolidated snapshot
3.5.4. — Dimensions and Signs
Content not available for this version.
3.5.4.1. — Elevator Car Dimensions
(1) If an elevator is installed to conform to the requirements of Article 3.3.1.7.v1, or if one or more elevators are provided in a building more than three storeys in building height, each storey having elevator service shall be served by at least one elevator that has inside dimensions that will accommodate and provide adequate access for a patient stretcher 2 010 mm long and 610 mm wide in the prone position
(2) An elevator satisfying the requirements of Sentence (1) shall be clearly identified on the main entrance level of the building.
Text · e-Laws consolidated snapshot
Provenance
OBC 1997 · continues from 3.5. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
OBC 2012 · continues as 3.5. — Pro