CodeChronicle

OBC 2006 Division B

3.4.6.6.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 3.4.6.6. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · renumbered to 3.4.6.7. — Pro

3.4.6.6. — Ramp Slope

(1) Except as required for aisles by Article 3.3.2.4.v1, the maximum slope of a ramp shall be,

(a) 1 in 10 in any assembly occupancy, care or detention occupancy or residential occupancy,

(b) 1 in 6 in rooms or floor areas classified as mercantile occupancy or industrial occupancy,

(c) 1 in 8 in any other floor area, and

(d) 1 in 10 for an exterior ramp.

Text · e-Laws consolidated snapshot