CodeChronicle

OBC 2006 Division B

3.4.6.18.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 3.4.6.18. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · renumbered to 3.4.6.19. — Pro

3.4.6.18. — Floor Numbering

(1) Arabic numerals indicating the assigned floor number shall,

(a) be mounted permanently on each side of doors to exit stair shafts,

(b) be not less than 60 mm high, raised approximately 0.7 mm above the surface,

(c) be located 1 500 mm from the finished floor, and

(d) be contrasting in colour with the surface to which they are applied.

(2) Upper case letters indicating the designation assigned to each exit stair shaft shall be mounted permanently on each side of doors to the exit stair shaft and shall,

(a) be not less than 60 mm high, raised approximately 0.7 mm above the surface,

(b) be located 1 500 mm from the finished floor, and

(c) be contrasting in colour with the surface on which they are applied.

Text · e-Laws consolidated snapshot