CodeChronicle

OBC 2006 Division B

3.3.2.9.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 3.3.2.9. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 3.3.2.9. — Pro

3.3.2.9. — Outdoor Places of Assembly

(1) A Group A, Division 4 occupancy and each tier or balcony that has a capacity of more than,

(a) 1 000 persons shall have no fewer than 3 separate exits, or

(b) 4 000 persons shall have no fewer than 4 separate exits.

(2) In a Group A, Division 4 occupancy, every seat shall be located so that the travel distance is not more than 45 m measured along the path of travel from the seat to,

(a) the ground,

(b) an exit,

(c) an opening to a passageway leading from the seating area, or

(d) a portal, a vomitory or any other opening through the seating deck structure.

(3) Exits from outdoor stadia or grandstands shall be located not more than 25 m apart.

(4) The capacity of a means of egress for a Group A, Division 4 occupancy shall conform to the requirements of Sentence 3.4.3.2.(3)v1.

(5) Aisles in a Group A, Division 4 occupancy,

(a) shall be located so that there are not more than 20 seats between any seat and the nearest aisle and

(b) shall be not less than 1 200 mm wide, except that an aisle serving less than 60 persons is permitted to be 750 mm wide

Text · e-Laws consolidated snapshot