OBC 2006 › Division B
3.2.6.10.
Version 0 — in force 31 December 2006
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 3.2.6.10.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next one commenced. What follows is that next version’s commencement — the event that ended this one.
15. This Regulation comes into force on April 1, 2010.
Read directly from the regulation's own commencement section.
O. Reg. 205/08 · commencement 15
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 3.2.6.10.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next one commenced. What follows is that next version’s commencement — the event that ended this one.
15. This Regulation comes into force on April 1, 2010.
Read directly from the regulation's own commencement section.
O. Reg. 205/08 · commencement 15
Provenance
OBC 1997 · continues from 3.2.6.10. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
O. Reg. 205/08, cl. 7 · ext v1 →
In force 2010-04-01
Next: O. Reg. 205/08, cl. 7 · ext (not in force until 2010-04-01) v1 →
Discontinued — no OBC 2012 successor
3.2.6.10. — Venting to Aid Fire Fighting
Comparing versions
Image-only version — shown side by side, no highlighting
v0 base
Earlier · viewing · 2006-12-31(1) Means of venting each floor area to the outdoors shall be provided by windows, wall panels or smoke shafts, except that in a sprinklered floor area, the floor area is permitted to be vented by the building exhaust system.
(2) Venting described in Sentence (1) shall conform to the requirements in Supplementary Standard SB-4.
(3) Fixed glass windows shall not be used for the venting required by Sentence (1) if the breaking of the windows could endanger pedestrians below.
(4) Openable windows used for the venting required by Sentence (1) shall be permanently marked so that they are easily identifiable.
(5) Elevator hoistways shall not be designed for the venting required by Sentence (1).
Text · e-Laws consolidated snapshot
v1 O. Reg. 205/08
Later · 2010-04-01Content not available for this version.
Provenance
OBC 1997 · continues from 3.2.6.10. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
O. Reg. 205/08, cl. 7 · ext v1 →
In force 2010-04-01 comparing ×
Next: O. Reg. 205/08, cl. 7 · ext (not in force until 2010-04-01) v1 →
Discontinued — no OBC 2012 successor