CodeChronicle

OBC 2006 Division B

3.2.2.82.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 3.2.2.82. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 3.2.2.82. — Pro

3.2.2.82. — Group F, Division 3, One Storey, Any Area, Low Fire Load Occupancy

(1) A building classified as Group F, Division 3 is permitted to conform to Sentence (2) provided it is,

(a) not more than 1 storey in building height,

(b) used solely for low fire load occupancies such as,

(i) power generating plants, or

(ii) plants for the manufacture or storage of noncombustible materials, and

(c) not limited in building area.

(2) The building referred to in Sentence (1) shall be of noncombustible construction.

Text · e-Laws consolidated snapshot