OBC 2006 › Division B
3.2.2.7.
Version 0 — in force 31 December 2006
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 3.2.2.7.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 3.2.2.7.
- Version
- v0
(1) This Regulation comes into force on December 31, 2006.
Read directly from the regulation's own commencement section.
O. Reg. 350/06 · commencement 2.2.1.1(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
Provenance
OBC 1997 · continues from 3.2.2.7. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
OBC 2012 · continues as 3.2.2.7. — Pro
3.2.2.7. — Superimposed Major Occupancies
(1) Except as permitted by Article 3.2.2.8., in a building in which one major occupancy is located entirely above another major occupancy, the requirements in this Subsection for each portion of the building containing a major occupancy shall apply to that portion as if the entire building was of that major occupancy.
(2) If one major occupancy is located above another major occupancy, the fire-resistance rating of the floor assembly between the major occupancies shall be determined on the basis of the requirements of this Subsection for the lower major occupancy.
Text · e-Laws consolidated snapshot
- B 3.2.2.6. v0
- B 3.2.2.20. v0
- B 3.2.2.23. v0
- B 3.2.2.24. v0
- B 3.2.2.26. v0
- B 3.2.2.27. v0
- B 3.2.2.29. v0
- B 3.2.2.31. v0
- B 3.2.2.33. v0
- B 3.2.2.36. v0
- B 3.2.2.37. v0
- B 3.2.2.38. v0
- B 3.2.2.39. v0
- B 3.2.2.40. v0
- B 3.2.2.41. v0
- B 3.2.2.42. v2
- B 3.2.2.43. v1
- B 3.2.2.45. v0
- B 3.2.2.48. v0
- B 3.2.2.49. v0
- B 3.2.2.51. v0
- B 3.2.2.52. v0
- B 3.2.2.54. v0
- B 3.2.2.56. v0
- B 3.2.2.57. v0
- B 3.2.2.58. v0
- B 3.2.2.60. v0
- B 3.2.2.62. v0
- B 3.2.2.63. v0
- B 3.2.2.64. v0
- B 3.2.2.65. v0
- B 3.2.2.67. v0
- B 3.2.2.72. v0
- B 3.2.2.72. v1
- B 3.2.2.73. v0
- B 3.2.2.75. v0
- B 3.2.2.77. v0
- B 3.2.2.79. v0
- B 3.2.2.81. v0
Provenance
OBC 1997 · continues from 3.2.2.7. — Pro
Base · O. Reg. 350/06 · ext← current
Original — base regulation
OBC 2012 · continues as 3.2.2.7. — Pro