CodeChronicle

OBC 2006 Division B

3.12.5.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · renumbered from 3.11A.5. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 3.12.5. — Pro

3.12.5. — Emergency Provisions for All Public Spas

Content not available for this version.

3.12.5.1. — Lighting and Emergency Provisions

(1) In addition to the requirements of this Subsection, public spas shall comply with the requirements of Sentences 3.11.10.1.(1) to (6).

(2) An emergency telephone directly connected to an emergency service or to the local telephone utility shall be installed within 30 m of the public spa.

(3) All pumps used in a public spa shall be capable of being deactivated by an emergency stop button that is clearly labelled and located within the immediate vicinity of the public spa.

(4) The emergency stop button required in Sentence (3),

(a) shall be a switch separate from the public spa’s timing device,

(b) shall activate an audible and a visual signal when used, and

(c) shall have an emergency sign conforming to Sentence 3.11.10.1.(14).

(5) If a public spa and public pool are located in the same room or space, the emergency stop buttons required in Sentences (3) and 3.11.10.1.(12) shall deactivate all pumps serving the public spa and public pool.

Text · e-Laws consolidated snapshot