CodeChronicle

OBC 2006 Division B

3.1.7.1.

Version 1 — in force 1 January 2010

In force · amended
Verified · covered Verified against the 2010-01-01–2010-03-31 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 3.1.7.1. — Pro

Base · O. Reg. 350/06 · ext v0 →

O. Reg. 503/09, cl. 16 · ext ← current

In force 2010-01-01

OBC 2012 · continues as 3.1.7.1. — Pro

3.1.7.1. — Determination of Ratings

(1) Except as permitted by Sentence (2) and Article 3.1.7.2., the rating of a material, assembly of materials or a structural member that is required to have a fire-resistance rating, shall be determined on the basis of the results of tests conducted in conformance with CAN/ULC-S101, “Fire Endurance Tests of Building Construction and Materials”.

(2) A material, assembly of materials or a structural member is permitted to be assigned a fire-resistance rating on the basis of Supplementary Standard SB-2.

Text · e-Laws consolidated snapshot