CodeChronicle

OBC 2006 Division B

3.1.5.23.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · split from 3.1.5.22. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 3.1.5.23. — Pro

3.1.5.23. — Marquees Having Combustible Elements

(1) Except as permitted in Sentence (2), exterior marquees, not greater than 7.5 m from ground level to the top of the marquee, having combustible elements other than fabrics or films conforming to Sentence 3.1.16. 1.(1), are permitted on a building required to be of noncombustible construction, provided every opening in the exposed wall of the building above the marquee is protected with wired glass in accordance with Supplementary Standard SB-2 where these openings are within,

(a) 4.5 m horizontally of the marquee, and

(b) 9 m vertically above the marquee.

(2) The protection required by Sentence (1) is permitted to be waived if the building is sprinklered.

Text · e-Laws consolidated snapshot