CodeChronicle

OBC 2006 Division B

3.1.14.1.

Version 0 — in force 31 December 2006

In force
Verified · covered Verified against the 2006-12-31–2007-04-01 consolidation, whose range covers the query date. How to read this

Provenance

OBC 1997 · continues from 3.1.14.1. — Pro

Base · O. Reg. 350/06 · ext← current

Original — base regulation

OBC 2012 · continues as 3.1.14.1. — Pro

3.1.14.1. — Fire-Retardant Treated Wood Roof Systems

(1) If a fire-retardant treated wood roof system is used to comply with the requirements of Subsection 3.2.2., the roof deck assembly shall meet the conditions of acceptance of CAN/ULC-S126-M, “Test for Fire Spread Under Roof-Deck Assemblies”.

(2) Supports for the roof deck assembly referred to in Sentence (1) shall consist of,

(a) fire-retardant treated wood,

(b) heavy timber construction,

(c) noncombustible construction, or

(d) a combination of the items described in Clauses (a), (b) and (c).

Text · e-Laws consolidated snapshot