CodeChronicle

OBC 2006 Division B

12.2.1.2.

Version 1 — in force 2 April 2007

In force · amended
Verified · covered Verified against the 2007-04-02–2007-06-30 consolidation, whose range covers the query date. How to read this

Provenance

New in this edition — no OBC 1997 predecessor

Base · O. Reg. 350/06 · ext v0 →

O. Reg. 137/07, cl. 71 · ext ← current

In force 2007-04-02

O. Reg. 503/09, cl. 219 · ext v2 →

In force 2010-01-01

O. Reg. 315/11, cl. 2 · ext v3 →

In force 2011-07-01

Next: O. Reg. 503/09, cl. 219 · ext (not in force until 2010-01-01) v2 →

OBC 2012 · renumbered to 12.2.1.1. — Pro

12.2.1.2. — Energy Efficiency Design After December 31, 2011

Comparing versions

Changed text stands out · unchanged is dimmed

v1 O. Reg. 137/07

Earlier · viewing · 2007-04-02

(1) Sentences (2) to (5) apply to construction for which a permit has been applied for after December 31, 2011.

(2) Except as provided in Sentences (3) and (5), the energy efficiency of all buildings shall be designed to exceed by not less than 25% the energy efficiency levels attained by conforming to the CCBFC, “Model National Energy Code for Buildings”.

(3) The energy efficiency of a building or part of a building of residential occupancy that is within the scope of Part 9 and is intended for occupancy on a continuing basis during the winter months shall meet the performance level that is equal to a rating of 80 or more when evaluated in accordance with NRCan “EnerGuide for New Houses: Administrative and Technical Procedures”.

(4) Reserved

(5) Sentence (1) does not apply to,

(a) farm buildings, and

(b) buildings intended primarily for manufacturing or commercial or industrial processing.

v2 O. Reg. 503/09

Later · 2010-01-01

(1) Sentences (2) to (5) apply to construction for which a permit has been applied for after December 31, 2011.

(2) Except as provided in Sentences (3) and (5), the energy efficiency of all buildings shall be designed to exceed by not less than 25% the energy efficiency levels attained by conforming to the CCBFC, “Model National Energy Code for Buildings”.

(3) The energy efficiency of a building or part of a building of residential occupancy that is within the scope of Part 9 and is intended for occupancy on a continuing basis during the winter months shall,

(a) meet the performance level that is equal to a rating of 80 or more when evaluated in accordance with NRCan, “EnerGuide for New Houses: Administrative and Technical Procedures”, or

(b) conform to Supplementary Standard SB-12.

(4) Reserved

(5) Sentence (1) does not apply to,

(a) farm buildings, and