OBC 2006 › Division B
12.2.1.1.
Version 2 — in force 1 January 2010
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 12.2.1.1.
- Version
- v2
240. (1) Subject to subsections (2), (3), (4), (5), (6) and (7), this Regulation comes into force on the later of January 1, 2010 and the day this Regulation is filed.
Read directly from the regulation's own commencement section.
O. Reg. 503/09 · commencement 240(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- B
- Provision
- 12.2.1.1.
- Version
- v2
240. (1) Subject to subsections (2), (3), (4), (5), (6) and (7), this Regulation comes into force on the later of January 1, 2010 and the day this Regulation is filed.
Read directly from the regulation's own commencement section.
O. Reg. 503/09 · commencement 240(1)
This version stayed in force until the next edition replaced it. What follows is that edition’s base regulation’s commencement — the takeover that ended this one.
(1) Subject to Sentences (2) and (3), this Regulation comes into force on January 1, 2014.
Read directly from the regulation's own commencement section.
O. Reg. 332/12 · commencement 4.4.1.1(1)
Provenance
OBC 1997 · renumbered from 2.1.1.11. — Pro
OBC 1997 · renumbered from 9.25.1.3. — Pro
Base · O. Reg. 350/06 · ext v0 →
O. Reg. 137/07, cl. 70 · ext v1 →
In force 2007-04-02
O. Reg. 503/09, cl. 218 · ext ← current
In force 2010-01-01
OBC 2012 · merged into 12.2.1.1. — Pro
12.2.1.1. — Energy Efficiency Design
Comparing versions
Changed text stands out · unchanged is dimmed
v1 O. Reg. 137/07
Earlier · 2007-04-02(1) Sentences (2) to (5) apply to construction for which a permit has been applied for before January 1, 2012.
(2) Except as provided in Sentences (3) and (5) and permitted in Sentence (4), the energy efficiency of all buildings shall be designed to good engineering practice such as described in,
(a) the ANSI/ASHRAE/IESNA 90.1, “Energy Standard for Buildings Except Low-Rrise Residential Buildings” and Supplementary Standard SB-10, or
(b) the CCBFC, “Model National Energy Code of Buildings” and Supplementary Standard SB-10.
(3) The energy efficiency of a building or part of a building of residential occupancy that is within the scope of Part 9 and is intended for occupancy on a continuing basis during the winter months shall,
(a) conform to the thermal insulation requirements of Subsection 12.3.2.,
(b) conform to the thermal design requirements of Subsection 12.3.3., or
(c) provide a rating of 80 or more when evaluated in accordance with NRCan “EnerGuide for New Houses: Administrative and Technical Procedures”
(4) The energy efficiency of a building or part of a building may conform to the design requirements of Subsection 12.3.4. if the building or part of the building,
(a) is within the scope of Part 9,
(b) does not contain a residential occupancy,
(c) does not use electric space heating, and
(d) is intended for occupancy on a continuing basis during the winter months.
(5) Sentence (1) does not apply to,
(a) farm buildings, and
(b) buildings intended primarily for manufacturing or commercial or industrial processing.
v2 O. Reg. 503/09
Later · viewing · 2010-01-01(1) Sentences (2) to (5) apply to construction for which a permit has been applied for before January 1, 2012.
(2) Except as provided in Sentences (3) and (5) and permitted in Sentence (4), the energy efficiency of all buildings shall be designed to good engineering practice such as described in,
(a) the ANSI/ASHRAE/IESNA 90.1, “Energy Standard for Buildings Except Low-Rrise Residential Buildings” and Supplementary Standard SB-10, or
(b) the CCBFC, “Model National Energy Code of Buildings” and Supplementary Standard SB-10.
(3) The energy efficiency of a building or part of a building of residential occupancy that is within the scope of Part 9 and is intended for occupancy on a continuing basis during the winter months shall,
(a) conform to the thermal insulation requirements of Subsection 12.3.2.,
(b) conform to the thermal design requirements of Subsection 12.3.3.,
(c) provide a rating of 80 or more when evaluated in accordance with NRCan “EnerGuide for New Houses: Administrative and Technical Procedures”, or
(d) conform to Supplementary Standard SB-12.
(4) The energy efficiency of a building or part of a building may conform to the design requirements of Subsection 12.3.4. if the building or part of the building,
(a) is within the scope of Part 9,
(b) does not contain a residential occupancy,
(c) does not use electric space heating, and
(d) is intended for occupancy on a continuing basis during the winter months.
(5) Sentence (1) does not apply to,
(a) farm buildings, and
(b) buildings intended primarily for manufacturing or commercial or industrial processing.
Provenance
OBC 1997 · renumbered from 2.1.1.11. — Pro
OBC 1997 · renumbered from 9.25.1.3. — Pro
Base · O. Reg. 350/06 · ext v0 → compare
O. Reg. 137/07, cl. 70 · ext v1 →
In force 2007-04-02 comparing ×
O. Reg. 503/09, cl. 218 · ext ← current
In force 2010-01-01
OBC 2012 · merged into 12.2.1.1. — Pro