80. (1) Subject to subsection (2), this Regulation comes into force on the day it is filed.
Read directly from the regulation's own commencement section.
O. Reg. 137/07 · commencement 80(1)
This version stayed in force until the next one commenced. What follows is that next version’s commencement — the event that ended this one.
240. (1) Subject to subsections (2), (3), (4), (5), (6) and (7), this Regulation comes into force on the later of January 1, 2010 and the day this Regulation is filed.
Read directly from the regulation's own commencement section.
O. Reg. 503/09 · commencement 240(1)
This looks wrong
Tell us what is wrong and we will verify & correct our mapping.
- Edition
- OBC_2006
- Division
- A
- Provision
- 1.3.1.2.
- Version
- v1
80. (1) Subject to subsection (2), this Regulation comes into force on the day it is filed.
Read directly from the regulation's own commencement section.
O. Reg. 137/07 · commencement 80(1)
This version stayed in force until the next one commenced. What follows is that next version’s commencement — the event that ended this one.
240. (1) Subject to subsections (2), (3), (4), (5), (6) and (7), this Regulation comes into force on the later of January 1, 2010 and the day this Regulation is filed.
Read directly from the regulation's own commencement section.
O. Reg. 503/09 · commencement 240(1)
Provenance
OBC 1997 · renumbered from 2.1.1.5. — Pro
OBC 1997 · renumbered from 9.40. — Pro
OBC 1997 · merged from 9.40.1. — Pro
OBC 1997 · merged from 9.40.1.1. — Pro
OBC 1997 · merged from 9.40.1.2. — Pro
Base · O. Reg. 350/06 · ext v0 →
O. Reg. 137/07, cl. 3 · ext ← current
In force 2007-04-02
O. Reg. 503/09, cl. 6(2) · ext v2 →
In force 2010-01-01
Next: O. Reg. 503/09, cl. 6(2) · ext (not in force until 2010-01-01) v2 →
OBC 2012 · continues as 1.3.1.2. — Pro
1.3.1.2. — Farm Buildings
Comparing versions
Changed text stands out · unchanged is dimmed
v1 O. Reg. 137/07
Earlier · viewing · 2007-04-02(1) Except as provided in Sentences (2) to (5), farm buildings shall conform to the requirements in the CCBFC, “National Farm Building Code of Canada”.
(2) Articles 1.1.1.2. and 3.1.8.1. and Subsections 3.1.4. and 4.1.4. in the CCBFC, “National Farm Building Code of Canada” do not apply to farm buildings.
(3) In the CCBFC, “National Farm Building Code of Canada”, references in Articles 1.1.1.3., 2.2.2.1., 2.2.2.2., 2.3.1.1., 2.3.2.1., 3.1.1.1., 3.1.1.2., 3.1.2.1. and 3.1.6.1. to the National Building Code of Canada are deemed to be references to Ontario Regulation 403/97 (Building Code) made under the Act, as that regulation read immediately before it was revoked.
(4) A farm building of low human occupancy having a building area not exceeding 600 m2 and not more than three storeys in building height is deemed to comply with the structural requirements of the CCBFC, “National Farm Building Code of Canada” if it is designed and constructed in conformance with Supplementary Standard SB-11.
(5) A manure storage tank shall comply with the requirements of Subsection 4.4.5. of Division B.
v2 O. Reg. 503/09
Later · 2010-01-01(1) Except as provided in Sentences (2) to (4), farm buildings shall conform to the requirements in the CCBFC, “National Farm Building Code of Canada”.
(2) Articles 1.1.1.2. and 3.1.8.1. and Subsections 3.1.4. and 4.1.4. in the CCBFC, “National Farm Building Code of Canada” do not apply to farm buildings.
(3) In the CCBFC, “National Farm Building Code of Canada”, references in Articles 1.1.1.3., 2.2.2.1., 2.2.2.2., 2.3.1.1., 2.3.2.1., 3.1.1.1., 3.1.1.2., 3.1.2.1. and 3.1.6.1. to the National Building Code of Canada are deemed to be references to Ontario Regulation 403/97 (Building Code) made under the Act, as that regulation read immediately before it was revoked.
(4) A farm building of low human occupancy having a building area not exceeding 600 m2 and not more than three storeys in building height is deemed to comply with the structural requirements of the CCBFC, “National Farm Building Code of Canada” if it is designed and constructed in conformance with Supplementary Standard SB-11.
(5) A liquid manure storage tank shall comply with the requirements of Part 4 of Division B of this Code and the requirements of Part 4 of the CCBFC, “National Farm Building Code of Canada”.
Provenance
OBC 1997 · renumbered from 2.1.1.5. — Pro
OBC 1997 · renumbered from 9.40. — Pro
OBC 1997 · merged from 9.40.1. — Pro
OBC 1997 · merged from 9.40.1.1. — Pro
OBC 1997 · merged from 9.40.1.2. — Pro
Base · O. Reg. 350/06 · ext v0 → compare
O. Reg. 137/07, cl. 3 · ext ← current
In force 2007-04-02
O. Reg. 503/09, cl. 6(2) · ext v2 →
In force 2010-01-01 comparing ×
Next: O. Reg. 503/09, cl. 6(2) · ext (not in force until 2010-01-01) v2 →
OBC 2012 · continues as 1.3.1.2. — Pro